We produce successful solutions for the use of electric power in maritime transport. In projects where our standard batteries are insufficient, we can complete new battery designs for our customers in a period of 6 months. Durable batteries that can be scaled according to the project have liquid cooling technology with heat management system.
20ft ESS Specifications | ||
---|---|---|
Parameter | Specification | Unit |
No. of Rack Cabinet | 7 | |
System Capacity | 1050 | Ah |
Pack Configuration | 192S3P | |
System Configuration | 192S21P | |
Installed System Energy | 735 | kWh |
Minimum Voltage | 576 | V |
Nominal Voltage | 701 | V |
Maximum Voltage | 806 | V |
Charge Power Cont. | 500 | kW |
Charge Power Peak @10s | 500 | kW |
Charge Current Cont. | 713 | A |
Charge Current Peak @10s | 713 | A |
Discharge Power Cont. | 500 | kW |
Discharge Power Peak @10s | 500 | kW |
Discharge Current Cont. | 713 | A |
Discharge Current Peak @10s | 713 | A |
Communication Protocol | CAN 2.0A | |
Operating Supply Voltage | 9-36 | V |
IP Class | IP20 | |
Cycle Life | > 5000 | |
Operating Temperature | -10...+45 | Celcius |
Cooling System | Air Cooled | |
Dimensions | 20ft container | |
Estimated Weight | 10000 | kg |
The architecture of the battery systems was created with NMC cell chemistry, conceptual design visuals are as above.
Container battery consists of the following subcomponents;
1. Cell groups (modular battery system),
2. BMS (Battery Management System),
3. PJB, inverter, cabling and various power electronic components,
4. Air conditioning system (heating / cooling capacity will vary
depending on the external environment conditions where the
container battery will be located),
5. Fire extinguisher / sprinkler system (Aerosol),
6. EMS (Energy Management System) and SCADA.